3 daily filtration operation – Frymaster YFPRE1817E User Manual
Page 19

YFPRE18E ELECTRIC FRYER
CHAPTER 4: BUILT-IN FILTRATION
4-4
4.2.2 Installing the Filter
Slide the filter inside the fryer cabinet. Ensure
the male-female slip-fitting coupling is fully
engaged.
4.3 Daily Filtration Operation
DANGER
Use caution and wear proper protective clothing. The oil to be filtered is at or near
350°F (177°C). Ensure all hoses are connected properly and drain handles are in
their proper position prior to operating any switches or valves. Failure to do this can
result in severe burns.
NOTICE
Drawings and photos used in this manual are intended to illustrate operational,
cleaning and technical procedures and may not conform to on-site management
operational procedures.
4.3.1 General Overview
The filter pump is turned on only after the oil is brought to operating temperature and drained into
the prepared filter pan. The filter motor is then engaged and oil is drawn through the filter pad and
pumped back into the frypot. The frypot’s drain remains open during the filtering process. Allow
the oil to cycle through the filter pad for approximately 30 minutes. At the end of 30 minutes, close
the drain valve and allow the pump to fill the frypot to the top OIL LEVEL line. Leave the pump
running for 15-30 seconds after bubbles appear in the frypot to ensure all oil is pumped from the
drain pan and the lines.
The filter pan is shown partially inserted under the
fryer.