Troubleshooting checklist

Symptom

Check this item

Remedy

Scanner does not turn on.

Have you pressed the power button on?

Push the power button in to turn the scanner.

Are the AC cable and AC adapter prop-

erly connected to the

scanner?

Correctly connect the AC cable and the AC

adapter.
Disconnect the AC cable and the AC adapter from

the scanner, then connect them again.

If this does not restore the power supply, contact
the store where you purchased the scanner or an

authorized FUJITSU scanner service provider.

Are you using the correct AC cable and

AC adapter supplied with the scanner

from the manufacture?

You must use the AC adapter and cable supplied

with your scanner by the

manufacture. Please get the correct AC adapter
and cable to connect to your scanner.

Scanning does not com-
mence.

Are the documents loaded properly on to
the ADF paper chute?

Realign and reload the documents on to ADF
paper chute.

Is the ADF closed completely?

Close the ADF completely.

Is the USB cable or SCSI cable con-

nected securely?

Connect the cable. (When a USB hub is used,

check the hub's power supply.)

When using a SCSI interface, Is SCSI

ID set correctly?

Use the SCSI ID switch at the rear of the scanner

to set the SCSI ID.

Does the Function Number display indi-

cates an alarm or an error?

When the Function Number display indicates an

alarm or an error, refer to the "Chapter 5. TROU-
BLESHOOTING" in the fi-5120C/fi-5220C

Operator’s Guide for removing the alarm or the

error.

The alarm status remain displayed even

after the scanner has been turned off and
on again?

Turn off and on the power button.

If this does not eliminate the alarm status, contact
the store where you purchased the scanner or an

authorized FUJITSU scanner service provider.

Vertical lines appear in the

generated image of the

scanned document.

Are the glass dirty?

Clean the glass as instructed in the Operator's

Guide "3. Daily Care".

The generated image shifts

or is distorted.

Are the documents loaded correctly?

Load the documents correctly.

Quality of generated image

is unsatisfactory.

Are the glass clean?

Clean dirty locations.

Multi feed frequently

occurs.

Do the documents satisfy the "Docu-

ment Quality" and the "Multi feed
Detection Conditions" in the chapter 6

of the fi-5120C/fi-5220C Operator’s
Guide?

Use the documents that satisfy the "Document

Quality" and the "Multi feed Detection Condi-
tions" in the chapter 6 of the fi-5120C/fi-5220C

Operator’s Guide.

Are the documents placed properly in
the ADF paper chute?

Fan the documents before scanning. Correctly
align the document stack and load them on the

ADF paper chute. Refer to "2.1 Installing the

Scanner" on page 3 for details.

Is the stack of document thicker than 5

mm?

Reduce the number of sheets of the stack to a

thickness of 5 mm or less.

Is the Pad ASSY dirty?

Clean the Pad ASSY. Refer to Operator's Guide in

"3.3. Cleaning the ADF".

Is the Pad ASSY worn out?

Replace the Pad ASSY. Refer to Operator's Guide

in "4.2. Replacing the Pad ASSY".