beautypg.com

FUJITSU MAF3364FC User Manual

Page 35

background image

3 - 4

C141-F037-02EN

3.2.2

Sense data (4-03-xx), (4-40-xx), (4-44-xx), and (4-C4-xx)

Sense data (4-03-xx), (4-40-xx), (4-44-xx), and (4-C4-xx) indicate one of the following:

A target sector could not be detected using the sector counter.

A seek process overran the specified time.

A write to a disk terminated abnormally.

An error occurred in power-on self-diagnosis.

A hardware error occurred inside IDD.

A drive error occurred.

The symptoms above are generally caused by an error in a PCA or DE.

For details of the sense data above, refer to the Fibre Channel Logical Interface Specifications.

3.2.3

Sense data (1-1x-xx), (3-1x-xx) and (E-1D-00): Disk read error

If sense data (1-1x-xx), (3-1x-xx) or (E-1D-00) occurs frequently in a specific block of a disk,
there is disk damage that was not recorded in the media defect list. In this case, assign an
alternate block to the error-detected block using a REASSIGN BLOCKS command. For an
explanation of the REASSIGN BLOCKS command, refer to the Fibre Channel Logical Interface
Specifications.

If this error occurs in different blocks, a PCA or DE is faulty.

For details of the above sense data, refer to the Fibre Channel Logical Interface Specifications.

3.2.4

Sense data (5-2x-xx), (5-3D-00), (5-90-00), (B-47-xx), (B-49-00) and (B-4E-00): fibre channel
interface error

Sense data (5-2x-xx), (5-3D-00), (5-90-00), (B-47-xx), (B-49-00), (B-4D-xx) and (B-4E-00)
indicates one of the following symptoms:

An invalid or unsupported command was issued, or invalid or unsupported parameters were
specified.

A fibre channel interface error occurred.

If this error occurs, a PCA or the fibre channel interface is faulty.

For details of the above sense data, refer to the SCSI Logical Interface Specifications.