T

WISTED

-P

AIR

C

ABLE

AND

P

IN

A

SSIGNMENTS

February 2003

© 2003 Foundry Networks, Inc.

B-3

network connections to PCs or servers, or to other switches or
hubs. The RJ-45 port on the 100BASE-TX module is an MDI-X
port, which allows you to use straight-through cable for
connections to PCs and servers. In straight-through cable, pins 1,
2, 3, and 6, at one end of the cable, are connected straight through
to pins 1, 2, 3, and 6 at the other end of the cable. For connection
to hubs or switches which have MDI-X ports, a crossover cable
must be used.

Pin

MDI-X Signal

Name

MDI Signal

Name

1

Receive Data plus
(RD+)

Transmit Data
plus (TD+)

2

Receive Data minus
(RD-)

Transmit Data
minus (TD-)

3

Transmit Data plus
(TD+)

Receive Data plus
(RD+)

6

Transmit Data
minus (TD-)

Receive Data
minus (RD-)

4,5,7,8

Not used

Not used

Note:

The “+” and “-” signs represent the polarity

of the wires that make up each wire pair.