5 filter after – Frymaster LOV BIGLA30 User Manual
Page 57
4-33
The computer displays
volume 1-9 on the left and 9 on the right.
3. Use the number keys to set volume level
. Select from
nine levels of volume with 1 being the softest and 9
the loudest.
4. Use the
t and
u buttons to scroll to tone 1-3.
The computer displays
tone 1-3 on the left and 1 on the right.
5. Use the number keys, to set the tone frequency from 1
to 3.
6. Press the (2) button to return to product
level 2 program
prompt.
7. Press the (2) button again to exit.
The computer displays
OFF.
4.13.5 FILTER AFTER
The AIF filtration mode uses two measures before prompting to filter. One checks for cook cycles
which is adjusted in this section and the other checks for time which is adjusted in the following
section 4.13.6 FILTER TIME. The prompt for filtration is initiated by whichever occurs first; either
the number of cycles elapsed or time elapsed.
The
FILTER AFTER option is used to set the number of cooking cycles which occur before the
filtration prompt is displayed.
1. Perform steps 1-3 on page 4-29 through 4-30.
Scroll to
FILTER AFTER.
2. With
FILTER after displayed, press the (1 yes) button.
The computer displays
filter after on the left and 0 or another number on the right.
3. Use the number keys from 0 to 9 to enter the number of
cook cycles before prompting to filter (ex. after every
12 cycles enter as 12).
The computer displays
filter AFTER on the left and 12 on the right.
4. Press the (2) button to return to product
level 2 program
prompt.