Calibrate fryer bi-weekly fr 2 b1 – Frymaster FR2 User Manual

Page 7

background image

Calibrate fryer

Bi-weekly

FR 2 B1

©McDonald’s Corporation · Planned Maintenance Manual · Revised June 2008

Page 1 of 2

Frymaster Fryer

All models using

an M2000 Computer

Bi-week

ly

FR 2 B1

Why

To maintain food safety standards

Time required

1 minutes to prepare

5 minutes to complete, once fryer has reached cooking
temperature. Cook temperature should be reached in
approximately 45 minutes.

Time of day

At open

For 24-hour restaurants: during low-volume periods

Hazard icons

Tools and supplies

Pyrometer with fry

vat probe

Neoprene Gloves

Procedure

1

Calibrate pyrometer.
Fill a hot beverage cup with
ice and then add cold water
from the drink tower up to
the top of the ice. You should
have 50 percent ice and 50
percent water.
2 Place probe in water
Place the probe in the ice wa-
ter and stir continuously until
the temperature readout
stabilizes.
3 Read temperature
The readout should be 32°F
(0°C), plus or minus 2°F
(1°C). If not, you need to
calibrate, repair, or replace
the pyrometer. For calibra-
tion, follow the calibration,
checking, and adjusting pro-
cedures supplied by the
manufacturer of your pyrome-
ter.


2

Turn on fryer and heat oil.
Press the on/off button to turn
the fryer on. Set the fryer for
the product to be cooked.
Allow the oil in the fryer to
reach cooking temperature
and then cycle off.

3

Check oil level.
Check the oil level when the
oil has reached cooking tem-
perature. If the oil is above
the “Oil Level” line, remove
oil until the oil is at the line
by draining oil into pan or
disposal unit. If the oil is
below the “Oil Level” line,
add oil until the oil reaches
the line.

Oil in the fryer is very hot.
Use gloves.

4

Cycle vat.
Allow the vat to cycle on and
off three times. The heat light
will come on when the fryer
is heating.