6.4 Troubleshooting the Built-In Filtration System (cont.)
A. Plugged openings or solidified
shortening in the Power Shower.
Test: Look for oil or shortening
squirting out around the Power
Shower gasket. If so, Power
Shower is obstructed.
A. Clean the Power Shower per
instructions in Chapter 5 of this
manual.
B. Missing/worn O-rings and gasket
on Power Shower.
B. Verify that O-rings and gasket are
present and in good condition.
Power Shower is not
spraying properly.
C. Missing paper in filter pan. (This
causes too much pressure in the
oil return lines, resulting in a
strong flow through the Power
Shower, but also squirting of oil
from around the gasket.)
C. Verify that filter paper is properly
installed in the filter pan.
6.5 Troubleshooting Abnormal Burner Operation
PROBLEM PROBABLE
CAUSES CORRECTIVE
ACTION
Fryer is operating
normally, but flames
are rolling out of the
front of the burner.
Obstructed gas valve vent tube.
Shut the fryer down and clean the gas
valve vent tube in accordance the
instructions on Page 5-4 – 5-5 of this
manual.