beautypg.com

Power factor pro manual – Furman Sound PF-Pro User Manual

Page 5

background image

power factor pro manual

(3) if all of the leds on the voltmeter

flash, the input voltage is marginally

high. Power to the Power factor

Pro’s outlets will remain on unless the

incoming voltage rises above the

extreme Voltage shutdown (eVs)

cut-off voltage (135 - 140 volts).

the Power factor Pro’s voltmeter has a basic

accuracy of plus or minus two volts, and
extreme cold or heat may cause an additional
one volt of error (four volts and two volts for
Power factor Pro e).

NOTE: although the Power factor correction

will more than compensate for peak current
demands, the Power factor Pro does not
compensate for sustained high or low line

voltage. if you derive power from generators,

travel internationally, or are in an area prone
to extreme brownouts, you may benefit from
the use of one of furman’s aC line Voltage
regulators.

on/off rocker Switch:

this 15 amp capacity power switch is

specifically designed to stand up to the
enormous high inrush current demands placed
by many instrument amplifiers. Additionally, the
semi-transparent rocker lights when switched

to the “on” position.

extreme Voltage Shutdown (eVS) Indicator:

this led is normally off. it monitors a hazard

unfortunately common in the entertainment
industry: wiring faults – for example, accidental
connection to 220VaC where 120VaC is
expected, or an open neutral from a 208 or

240VaC feed. the Power factor Pro’s sMP+

circuit senses voltages that are so high that
operation would be impossible and shuts the
power down before damage can occur. upon
initially applying power to these units, the
extreme Voltage indicator led will be lit if the
input voltage is above the extreme voltage
cutoff, and power will not be applied to the
unit’s outlets. if the unit has been operating
with an acceptable input voltage and then that

voltage goes above 135V, it will shut off power

to the outlet and the extreme Voltage led will
light.

note: if the mains power is above the high
cutoff voltage and has caused the unit to
remove power from its outlets, it cannot restore
power without the operator manually turning
the unit off, then on again. avoid turning the
unit back on without checking the source of the
problem first, and perhaps changing the AC
source.

4

Mains Vltg. Voltage Status

Voltmeter Reading

Outlets

80-90

Low Marginal

The 90V LED mark flashes

ON

90-104

low

Meter reads in low red

on

106-108

Medium low

Meter reads in low Yellow

on

110-120

normal

Meter reads in Green

on

122-124

Medium High

Meter reads in High Yellow

on

126-128

High

Meter reads in High red

on

130-140

High Marginal

all Meter leds flash

on

above 140

extreme (shutdown)

Meter off—extreme Voltage led illuminates off

This manual is related to the following products: