Frymaster BIGLA30 User Manual
Page 83
7-5
Problem
Probable Causes
Corrective Action
Frypots won’t top off.
A. Fryer temperature too low.
B. Oil is too cold.
C. JIB out of oil (yellow light illuminated)
D. Service required error exists
A. Fryer temperature must be at
setpoint.
B. Ensure that the oil in the JIB is
above 70°F (21°C).
C. Ensure the JIB is not out of oil.
Replace JIB and reset yellow LED.
If problem persists c
all your ASA
for assistance.
D
.
Call your ASA for assistance.
7.2.5 Bulk Oil System Problems
Problem
Probable Causes
Corrective Action
JIB won’t fill.
A. Incorrect setup procedure.
B. Another function is in process.
C. Dispose valve not completely closed.
D. Bulk oil tank is empty.
E. Solenoid, pump or switch issue.
A. Power cycle fryer by disconnecting
and reconnecting 5-pin control
power cord.
B. If a filtration or any other filter
menu function is in process or
FILTER NOW? YES/NO,
CONFIRM YES/NO, or SKIM VAT
are displayed, wait until the process
is complete and try again.
C. Ensure the dispose valve handle is
pushed fully closed.
D. Call your bulk oil provider.
E.
Call you ASA for assistance.
JIB or vat filling slow.
A. Pump or line issues beyond the scope of
operator troubleshooting.
A. Contact your bulk oil provider.
Frypot won’t fill.
A. Incorrect setup procedure.
B. Dispose valve not completely closed.
C. Bulk oil tank is empty.
D. RTI pump issue.
A. Power cycle fryer by disconnecting
and reconnecting 5-pin control
power cord.
B. Ensure the dispose valve handle is
pushed fully closed.
C. Call your bulk oil provider.
D. Call you ASA for assistance.
7.2.6 Error Log Codes
Code ERROR
MESSAGE
EXPLANATION
E03
ERROR TEMP PROBE FAILURE
TEMP Probe reading out of range
E04
HI 2 BAD
High limit reading is out of range.
E05
HOT HI 1
High limit temperature is past more than 410°F
(210°C), or in CE countries, 395°F (202°C)
E06
HEATING FAILURE
A component has failed in the high limit circuit
such as computer, interface board, contactor or
open-high limit.
E07
ERROR MIB SOFTWARE
Internal MIB software error
E08
ERROR ATO BOARD
MIB detects ATO board connection lost; ATO
board failure
E09
ERROR PUMP NOT FILLING
Dirty pad and it needs changed or it was
bypassed; filter pump problem
E10
ERROR DRAIN VALVE NOT OPEN
Drain valve was trying to open and confirmation
is missing