ScanSnap S500 Getting Started | 21

5.

Close the ADF cover

You should hear the ADF cover click into position

when it returns to its original position.

6.

Turn on the scanner.

ScanSnap Manager icon changes from

to

.

7.

Right click the "ScanSnap Manager" icon

on the

task tray, and select [Check consumable supplies]
from the menu.

8.

In the “Check consumable status” window, click the
[Reset] button of Pad ASSY Count.

The counter is reset to “0”.

6.3. Replacing the Pick Roller

Replace the Pick roller following the procedure below.

1.

Remove the document on the Paper chute cover.

2.

Open the ADF cover while pulling the Cover open
lever.

3.

Adjust the Side guide to the “A5” size.

4.

Remove the Sheet guide.
Pinch the handle on the Sheet guide to remove it.

5.

Rotate the Pick roller bushing (left side) in the
direction of the arrow.

6.

Remove the Pick roller with its shaft.
Slightly pull up the left part of the Pick roller shaft
(about 5mm), move it towards the left side, and then
raise it to remove from the scanner.

A5

A5

ADF cover

Paper chute
cover

Cover open lever

S

S

Pick roller

Pick roller shaft

Pick roller
shaft

Pick roller

bushing

Pick roller

Sheet guide

Handle

Claw

ADF cover