2

Electrical rating: • 24 VAC (18-30 VAC)

• DC Power: 3.0 VDC (2 “AA” batteries included)

• 1 amp maximum per terminal

• 3 amp maximum total load

Temperature control range: 45°F to 90°F (7°C to 32°C) Accuracy: ± 1°F (± 0.5°C)
System confi gurations: 1-stage heat, 1-stage cool, heat pump, electric
Timing:

Anti-short Cycle: 5 minutes

Backlight Operation: Battery for 5 seconds, hardwired for 10 seconds

Terminations: RC, RH, W, Y, B, O, GL, GH, C

Specifications

Important Safety Information

warning!: Always turn off power at the main power supply before installing, cleaning, or removing

thermostat.

• This thermostat is for 24 VAC applications only; do not use on voltages over 30 VAC
• Do not short across terminals of system control to test operation; this will damage your thermostat and void your

warranty

• All wiring must conform to local and national electrical and building codes
• Do not use air conditioning when the outdoor temperature is below 50 degrees; this can damage your A/C system

and cause personal injuries

• Use this thermostat only as described in this manual

Package Contents/Tools Required

Package includes: RT5 thermostat on base, thermostat cover, wiring labels, screws and wall anchors, Installation,

Operation and Application Guide