beautypg.com

Caution – Furuno 1932 MARK-2 User Manual

Page 10

background image

1-3

2. Lay the scanner unit on the mounting plat-

form, orienting it as shown in Figure 1-6.

STERN

BOW

Figure 1-6 Scanner unit (Shown: XN12A)

CAUTION

Do not lift the scanner unit by the
radiator; lift it by the housing.

The radiator may be damaged.

3. Insert four hex bolts and seal washers

from the top of the scanner housing. In-
sert the seal washers with the larger di-
ameter next to the bolt heads. Be sure
the seal washer, not other washers, is next
to bolt head.

Hex bolt

Seal washer

Flat washer

Spring washer

Nut

Figure 1-7 Fixing the scanner unit chassis

4. Pass flat washers, spring washers and

nuts onto hex bolts. Fasten by tightening
nuts. Do not fasten by tightening the hex
bolts; seal washers may be damaged.

Scanner
unit

Mounting
platform

Silicone
sealant

Flat washer

Rubber mat

Seal washer

Figure 1-8 How to fasten scanner unit to

mounting platform

5. Coat flat washers, spring washers, nuts

and exposed parts of bolts with anticor-
rosive sealant.

6. Prepare ground point in mounting platform

(within 300 mm of ground terminal on
scanner unit) using M6 x 25 bolt, nut and
flat washer.

7. Run the ground wire (RW-4747, 370 mm)

between the ground terminal and ground
point.

8. Coat ground terminal and ground point

with silicone sealant as shown in Figure
1-9.

Ground
terminal

Hex bolt

Flat washer

Spring washer

Flat washer

Hex nut

Silicone
sealant

Hex nut

Weld here.

Silicone
sealant

Ground
wire

Scanner
unit

OR

Flat washer

Spring washer

Ground
wire

GROUND

POINT

Hex nut

GROUND

TERMINAL

Figure 1-9 How to coat ground point and

ground terminal with silicone sealant