Frymaster FOOTPRINT E4 User Manual
Page 80
2-39
2.7 Frypot Assemblies and Associated Parts cont.
ITEM PART
#
COMPONENT
1
Frypot Assembly
(does not include Item 6)
2 823-5545SP
Frypot, Full-Vat Filter with Insulation
(for use on EPRI units)
3 823-5359SP
Frypot, Full-Vat Filter w/o Insulation
(for use on Standard units)
823-5996
Frypot, Half-Vat Filter w/o Insulation LH
(for use on Fryer ½ LH units)
823-5723
Frypot, Half-Vat Filter w/o Insulation RH
(for use on Fryer ½ RH units)
823-5783
Frypot, Full-Vat Filter w/o Insulation Deep Cabinet
(for use on Standard Deep units)
4 823-5551SP
Frypot, Dual-Vat Filter with Insulation
(for use on EPRI units)
5 823-5482SP
Frypot, Dual-Vat Filter w/o Insulation
(for use on Standard units)
√ 6
Thermostat
Assembly,
High-Limit
826-2454
Non-CE Full Vat 425°F (218°C) (17kW FV and 14kW FV)
(Color-Coded
Black 806-7543)
826-2456
Non-CE Dual Vat 435°F (224°C) (22kW, 17kW DV and 14 kW DV)
(Color-
Coded Red 806-8035)
826-2455
CE 415°F (213°C) (14kW and 17kW CE)
(Color-Coded Yellow 806-8132)
826-2457
CE 405°F (207°C) (22 kW FV and DV CE)
(Color-Coded White 806-8536)
7
812-0211
Insulation, Kaowool 17-inch X 10-inch X ½-inch
(4 required per pot)
8
900-4100
Retainer, Side Insulation
9
900-4101
Retainer, Front Insulation
10
900-1345
Retainer, Rear Insulation
11
826-1376
Nut, 10-32 Keps Hex
(Pkg. of 10)
NOTES:
The frypots for EPRI-equipped units are insulated; those for non-EPRI (standard) units are
not. EPRI frypot assemblies 806-5545SP and 806-5551SP consist of Items 2 and 4 respectively, plus
insulation (Items 7-10). When replacing insulation or adding insulation to a bare frypot, the individual
pieces (sides, front, and back) are cut to fit from Item 7 when installed. Each frypot requires four uncut
pieces of insulation.
√ Recommended parts.