ELECTRICAL POWER SPECIFICATIONS
Three (3) Phase Requirements
kW VOLTAGE
PHASE
WIRE
SERVICE
MINIMUM SIZE
AMPS PER LEG
AWG mm2 L1 L2
L3
14 208
3
3
6
16
39
39
39
14 240
3
3
6
16
34
34
34
14 480
3
3
8
10
17
17
17
14 220/380
3 4 6
16
21
21
21
14 240/415
3 4 6
16
20
20
21
14 230/400
3 4 6
16
21
21
21
ALL
EPRI 14kW
(SOLID STATE)
208 3 3 6 16
39
39
39
240 3 3 6 16
34
34
34
220/380 3
4
6 16 21
21
21
240/415 3
4
6 16 20
20
20
17 208
3
3
6
16
48
48
48
17 240
3
3
6
16
41
41
41
17 480
3
3
6
16
21
21
21
17 220/380
3 4 6
16
26
26
26
17 240/415
3 4 6
16
24
24
24
17 230/400
3 4 6
16
25
25
25
ALL
EPRI 17kW
(SOLID STATE)
208 3 3 6 16
48
48
48
240 3 3 6 16
41
41
41
220/380 3
4
6 16 26
26
26
240/415 3
4
6 16 24
24
24
22 208
3
3
4
25
61
61
61
22 240
3
3
4
25
53
53
53
22 480
3
3
6
16
27
27
27
22 220/380
3 4 6
16
34
34
34
22 240/415
3 4 6
16
31
31
31
22 230/400
3 4 6
16
32
32
32
Single Phase Requirements
kW VOLTAGE
PHASE
WIRE
SERVICE
MINIMUM SIZE
AMPS
AWG mm2
14 208
1
2
3
34 68
14 240
1
2
4
25 59
14 480
1
2
8
10 30