Annual/Periodic System Inspection


This appliance should be inspected and adjusted periodically by qualified service personnel as
part of a regular kitchen maintenance program.

Frymaster recommends that this appliance be inspected at least annually by a Factory
Authorized Service Technician as follows:


Fryer

• Inspect the cabinet inside and out, front and rear for excessive oil build-up and/or oil migration.

• Verify that the heating element wires are in good condition and that leads have no visible fraying

or insulation damage and that they are free of oil migration build-up.

• Verify that heating elements are in good condition with no carbon/caramelized oil build-up.

Inspect the elements for signs of extensive dry-firing.

• Verify that the tilt mechanism is working properly when lifting and lowering elements, and that

the element wires are not binding and/or chafing.

• Verify the heating-element amp-draw is within the allowed range as indicated on the appliance’s

rating plate.

• Verify that the temperature and high-limit probes are properly connected, tightened and

functioning properly, and that mounting hardware and probe guards are present and properly
installed.

• Verify that component box and contactor box components (i.e. computer/controller, relays,

interface boards, transformers, contactors, etc.) are in good condition and free from oil migration
build-up and other debris.

• Verify that component box and contactor box wiring connections are tight and that wiring is in

good condition.

• Verify that all safety features (i.e. contactor shields, drain safety switches, reset switches, etc.)

are present and functioning properly.

• Verify that the frypot is in good condition and free of leaks and that the frypot insulation is in

serviceable condition.

• Verify that all wiring harnesses and connections are tight and in good condition.


Built-In Filtration System

• Inspect all oil-return and drain lines for leaks and verify that all connections are tight.

• Inspect the filter pan for leaks and cleanliness. If there is a large accumulation of crumbs in the

crumb basket, advise the owner/operator that the crumb basket should be emptied into a fireproof
container and cleaned daily.