International kessel service – Frymaster H14 User Manual
Page 18
4-6
WARNING
The filter pump is equipped with a manual reset switch in case the filter motor
overheats or an electrical fault occurs. If this switch trips, turn off power to the filter
system and allow the pump motor to cool 20 minutes before attempting to reset the
switch.
In FootPrint III units, pull the filter base assembly out to access the pump motor. In
Filter Magic II units, the reset switch can be reached through the door of the FM II
cabinet without pulling out the filter pan assembly. In both cases, the reset switch is
the red button located on the face of the motor.
7. Lower the elements into the frypot and reinstall the basket support rack.
8. Ensure the drain valve is fully closed. (If the drain valve is not fully closed, the controller will
display an error message or a trouble light and the fryer will not operate.) Turn the fryer ON and
allow the cooking oil/shortening to reach setpoint.
DANGER
The crumb tray in fryers equipped with a filter system must be emptied into a
fireproof container at the end of frying operations each day. Some food particles
can spontaneously combust if left soaking in certain shortening material.
WARNING
Do not bang fry baskets or other utensils on the fryer’s joiner strip. The strip is
present to seal the joint between the fry vessels. Banging fry baskets on the strip to
dislodge shortening will distort the strip, adversely affecting its fit. It is designed for
a tight fit and should only be removed for cleaning.
INTERNATIONAL KESSEL SERVICE
WWW.INTERNATIONALKESSEL.COM