Mb3878 – FUJITSU MB3878 User Manual
Page 8

MB3878
8
(Continued)
(Ta
=
+
25
°
C, VCC
=
19 V, VCC (O)
=
19 V, VREF
=
0 mA)
* : Standard design value
Parameter
Symbol
Pin
No.
Conditions
Value
Unit
Min
Typ
Max
Current detection
amplifier block
(Current Amp.1,
Current Amp.2)
Output voltage
V
OUTCH
2, 10
4.7
4.9
V
V
OUTCL
2, 10
20
200
mV
Output source
current
I
SOURCE
2, 10 OUTC1
=
OUTC2
=
2 V
−
2.0
−
0.6
mA
Output sink
current
I
SINK
2, 10 OUTC1
=
OUTC2
=
2 V
150
300
µ
A
PWM comparator
block
(PWM Comp.)
Threshold voltage
V
TL
5, 7,
15
Duty cycle
=
0
%
1.4
1.5
V
V
TH
5, 7,
15
Duty cycle
=
100
%
2.5
2.6
V
Output block
(OUT)
Output source
current
I
SOURCE
20
OUT
=
11 V, Duty
≤
5
%
(t
=
1
/
f
OSC
×
Duty)
−
200*
mA
Output sink
current
I
SINK
20
OUT
=
16 V, Duty
≤
5
%
(t
=
1
/
f
OSC
×
Duty)
200*
mA
Output ON
resistor
R
OH
20
OUT
=
−
45 mA
8.0
12.0
Ω
R
OL
20
OUT
=
45 mA
6.5
9.7
Ω
Rise time
tr1
20
OUT
=
3300 pF
(equivalent to Si4435
×
1)
70*
ns
Fall time
tf1
20
OUT
=
3300 pF
(equivalent to Si4435
×
1)
60*
ns
Control block
(CTL)
CTL input voltage
V
ON
14
Active mode
2
25
V
V
OFF
14
Standby mode
0
0.8
V
Input current
I
CTLH
14
CTL
=
5 V
100
200
µ
A
I
CTLL
14
CTL
=
0 V
0
1
µ
A
Bias voltage
block (VH)
Output voltage
VH
19
VCC
=
VCC (O)
=
7 V to 25 V,
VH
=
0 to 30 mA
V
CC
−
5.5
V
CC
−
5.0
V
CC
−
4.5
V
General
Standby current
I
CCS
18,
19
VCC
=
VCC (O) ,
CTL
=
0 V
0
10
µ
A
Power supply
current
I
CC
18,
19
VCC
=
VCC (O) ,
CTL
=
5 V
8.0
12.0
mA