Usage precautions, Ordering information, Mb3878 – FUJITSU MB3878 User Manual
Page 22

MB3878
22
■
■
■
■
USAGE PRECAUTIONS
• Printed circuit board ground lines should be set up with consideration for common impedance.
• Take appropriate static electricity measures.
• Containers for semiconductor materials should have anti-static protection or be made of conductive material.
• After mounting, printed circuit boards should be stored and shipped in conductive bags or containers.
• Work platforms, tools, and instruments should be properly grounded.
• Working personnel should be grounded with resistance of 250 k
Ω
to 1 M
Ω
between body and ground.
• Do not apply negative voltages.
The use of negative voltages below –0.3 V may create parasitic transistors on LSI lines, which can cause
abnormal operation
■
■
■
■
ORDERING INFORMATION
Part number
Package
Remarks
MB3878PFV
24-pin plastic SSOP
(FPT-24P-M03)