DEAN MILLIVOLT GAS FRYERS (NON-CE)
CHAPTER 3: INSTALLATION INSTRUCTIONS
3-7
3.4 Gas Connections (cont.)
WARNING
Use a diluted soap solution to find potentially dangerous gas leaks when making
new connections.
B. Regulators: Gas regulators can be adjusted in the field, but no adjustments should be made
unless the regulator is out of adjustment, or serious pressure fluctuations are observed.
C. Only qualified service personnel should make adjustments to the regulators.
D. Orifices: The fryer can be configured to operate on any available gas. The correct safety
control valve, appropriate gas orifices, and pilot burner are installed at the factory. While
the valve can be adjusted in the field, only qualified service personnel should make any
adjustments with the proper test equipment.
E. Flexible Couplings, Connectors and Casters
1. If the fryer is to be installed with flexible couplings and/or quick-disconnect fittings, the
installer must use a heavy-duty certified commercial flexible connector of at least 3/4"
(22 mm) NPT (with suitable strain-relief attachments), in compliance with local codes or
in the absence of local codes, with the appropriate national standards. Quick-disconnect
devices must comply with local codes or in the absence of local codes, with the
appropriate national standards.
2. For an appliance equipped with casters, the installation shall be made with a connector
that complies with local codes or in the absence of local codes, with the appropriate
national standards.
3. Under no circumstances are the connector and the quick-disconnect device, or its
associated piping to be used to limit fryer movement. A restraining bracket is provided on
the appliance back to prevent the unit from moving from its installed position.
WARNING
Do not attach accessories to this fryer unless fryer is secured from tipping.
Personal injury may result.
4. To limit movement of the fryer, restraints independent of the flexible coupling or
connector must be used. Clips are located on the back panel of the fryer for the
attachment of restraints.
5. If disconnection of the restraint is necessary, the restraint must be reconnected after the