Frymaster SM60 User Manual
Page 14

DEAN MILLIVOLT GAS FRYERS (NON-CE)
CHAPTER 2: IMPORTANT INFORMATION
2-4
2.5 Pre-Installation (cont.)
C.
Installation Standards
1. INSTALLATION
STANDARDS: Fryer installation must conform with local codes, or in
the absence of local codes, to the appropriate national standards as listed below:
a. U.S. installations must meet:
b. Canadian installations must meet:
American National Standard Institute
CAN 1-B149 Installation Codes
ANSI Z83.11
Canadian Gas Association
American Gas Association
55 Scarsdale Road
8501 E. Pleasant Valley Road
Don Mills, ONT, M3B 2R3
Cleveland, OH 44131
National Electrical Code
Canadian Electric Code c22.1, part 1
ANSI/NFPA #70
Canadian Standards Association
American National Standard Institute
178 Rexdale Blvd.
1430 Broadway
Rexdale, ONT, M9W 1R3
New York, NY 10018
NFPA Standards #96 and #211
National Fire Protection Association
470 Atlantic Avenue
Boston, MA 02110
D. Australian Requirements
To be installed in accordance with AS 5601 / AG 601, local authority, gas, electricity, and any other
relevant statutory regulations.
2.6 Equipment Installed at High Altitudes
1. The fryer input rating [BTU/hr (kW/hr)] is for elevations up to 2,000 feet (610-m). For
elevations above 2,000 feet (610-m), the rating should be reduced 4-percent for each additional
1,000 feet (305-m) above sea level.
2. The correct orifices are installed at the factory if the operating altitude is known at the time of the
customer’s order.