beautypg.com

General operating problems, Troubleshooting, General operation – Meridian Audio 568 User Manual

Page 113

background image

106

Troubleshooting

Standby point not lit

Check the following:

❍ There is AC power connected to the socket on the rear of the

568.

❍ The power switch on the rear panel of the 568 is turned on.

If the 568 will still not illuminate, check any fuses in your power

supply and the fuse in the inlet of the 568. If these are all intact,

contact your dealer.

Erratic or unexpected system
behaviour

Redo the Auto Configure process as follows:

❍ Put the whole system into standby.
❍ Press Clear on the Meridian System Remote.
❍ Observe all units responding correctly.

If this fails, the memory of the 568 may have been corrupted. If

this is suspected perform a full reset; see Choosing a standard

setting, page 64.

Remote not working

Check the following:

❍ The battery in the Meridian System Remote.
❍ Remove the 500 Comms connections from the 568, does it

respond now? If so, replace the connections and perform an

Auto Configure procedure as described opposite.

❍ See if the 568 has been set up as not controller in the

Meridian Configuration program; see Changing the setup

options, page 96. Note that this may be deliberate by your

dealer.