FUJITSU MHA2032AT User Manual
Page 128

5.3 Host Commands
C141-E042-01EN
5-67
At command completion (I-O register contents)
1F7
H
(CM)
Status information
1F6
H
(DH)
Ч
Ч
Ч
DV
xx
1F5
H
(CH)
1F4
H
(CL)
1F3
H
(SN)
1F2
H
(SC)
1F1
H
(ER)
xx
xx
xx
xx
Error information
5.3.3 Error posting
Table 5.7 lists the defined errors that are valid for each command.
Table 5.13 Command code and parameters (1 of 2)
Command name
Error register (X’1F1’)
Status register (X’1F7’)
BBK
UNC
INDF
ABRT
TK0NF
DRDY
DWF
CORR
ERR
READ SECTOR(S)
V
V
V
V
V
V
V
V
WRITE SECTOR(S)
V
V
V
V
V
V
READ MULTIPLE
V
V
V
V
V
V
V
V
WRITE MULTIPLE
V
V
V
V
V
V
READ DMA
V
V
V
V
V
V
V
V
WRITE DMA
V
V
V
V
V
V
WRITE VERIFY
V
V
V
V
V
V
V
V
READ VERIFY SECTOR(S)
V
V
V
V
V
V
V
V
RECALIBRATE
V
V
V
V
V
SEEK
V
V
V
V
V
INITIALIZE DEVICE
PARAMETERS
V
V
V
V
IDENTIFY DEVICE
V
V
V
V
IDENTIFY DEVICE DMA
V
V
V
V
V:
Valid on this command
*:
See the command descriptioms.