background image

2. WIRING

2-6

2.2.4

Connection of Terflex

®

linear sensor

When connecting the Teleflex

®

linear sensor AR4102/AR4302 instead of the FAP-6111, do

the following modification.

1. Cut the black jumper at the back of the AR4102/4302.

DO NOT cut the red jumper.

2. Make the cable connection as shown below.
3. Change the position of jumper switch JP-2 from #3-4 to #1-2, referring to the illustration

shown on page 2-4.

4. Set SELECT RRU to “LINEAR SENSOR” on the DOCKSIDE SETUP menu. For further

details, see chapter 3.

1
2
3
4
5

SPU Board

(64P1140)

TB13

Linear sensor

AR4102

or

AR4302

RED

WHT

BLK

Processor unit

For BARE line, wind tape around where shield was removed.

Connection of linear sensor AR4102/AR4302