Installation instructions (Ice & Water only)
11
Attach double sided foam to the back of the water filter head as shown
in Diagram 5. Write the date to be replaced on the filter (date installed
+ 6 months). Remove double sided foam backing and attach filter to the
desired position as located in step 10 (refer to previous page).
12
Run the 6 mm (¼”) tubing to the back of the refrigerator ensuring there is
enough tubing to pull out the refrigerator for service.
13
Connect tubing into the water (solenoid) valve located on the right hand
side of the unit (compressor) compartment as shown in Diagram 7. Beware
of hot pipes.
14
Pull gently on tubing to ensure it is locked in as shown in Diagram 8.
15
The completed installation should look like Diagram 9 on page 11.
Fig.8 Waterline connection
to refrigerator
Diagram 7
Diagram 6
Diagram 8
16
Turn isolating tap on and check that all connections are dry and free of drips.
17
Coil water line tubing behind the refrigerator. Push your refrigerator into place being careful not
to kink or squash the water line running into the water (solenoid) valve.
18
Read pages 12 – 15 carefully, and then turn the refrigerator on.
19
The first time you require water out of the dispenser, there will be a delay while the water
reservoir fills up.
20
Run a further 3 litres (3 qt) through the system, stopping intermittently to ensure the reservoir is
flushed out. Failure to do this will result in excessive dripping from your dispenser.
21
On your display press the
button until the Ice menu is highlighted. Then press to turn
on the ice maker. Press and hold together to force a cycle. The ice tray will flip. Force
another cycle. The ice tray will flip and spill water into the ice bin. Empty water and replace bin.
22
You are now ready to enjoy automatic ice dispensing and chilled water from your Active Smart™
refrigerator. Please note that once installation is complete, a few drips may appear out of the
dispenser over the next few days as the remaining trapped air is cleared.