4-4
Setting method 1: by gyrocompass specifications
1) Gyrocompass type
2) Frequency
Gyrocompass
type
SW
1-4
SW
1-5
SW
1-6
JP1
Frequency
SW
1-7
SW
1-8
Remarks
AC synchronous
OFF
OFF
OFF #1,
#2, #3
50/60Hz
OFF
OFF
AC synchronous
pulsating current
DC synchronous
OFF
OFF
OFF #2,
#3, #4
400Hz
ON
OFF
AC synchronous
pulsating current
DC step
ON
OFF
OFF #4,
#5, #6
500Hz
OFF
ON
AC synchronous
pulsating current
Full-wave
pulsating current
OFF
ON
OFF #4,
#5, #6
DC
ON
ON
DC synchronous
DC step
Half-wave
pulsating current
ON
ON
OFF #4,
#5, #6
3) Rotor voltage
(between R1 & R2)
4) Stator voltage
(between S1 and S2)
Rotor voltage
SW 2-1
JP3
Stator voltage
SW 2-2
SW 2-3
JP2
20V to 45V AC
ON
#2
20V to 45V AC, or
20V to 60V DC
ON
OFF
#2
30V to 70V AC
OFF
#2
40V to 90V AC
ON
#1
20V to 45V AC, or
20V to 60V DC
OFF
OFF
#2
60V to 135V AC
OFF
#1
40V to 90V AC
ON
OFF
#1
60V to 135V AC
OFF
OFF
#1
5) Ratio
6) Supply voltage
Ratio
SW1-1
SW 1-2
SW1-3
Supply voltage
JP4
JP5
360x
OFF
OFF
OFF
20V to 45V AC, or
20V to 60V DC
#2
#2
180x
ON
OFF
OFF
90X
OFF
ON
OFF
30V to 135V AC, or
40V to 100V DC
#1
#1
36X
ON
ON
OFF
7) AD-10 format data
Tx interval
8) NMEA-0183
Tx interval
Select data transmitting interval for ports 1 to 6 by jumper wires
JP6 and JP7.
Tx
interval
SW2-4
Note: The Tx interval is available in 25 msec or 200 msec. 25
msec is for radar; 200 msec is for all other equipment.
2 seconds
ON
1 second
OFF