beautypg.com

Furuno FR-2155 User Manual

Page 24

background image

2-2

6. Determine the length of each core considering its location on STB-1 in the

scanner unit (see the interconnection diagram on page S-1). Remove approx.
6 mm of the vinyl insulation from the end of each core and fix the crimp-on lug
FV1.25-M3 (Red) to each core.

STB-2

STB-1

STB-3

Photo No.2872

Figure 2-3 Scanner unit, cover opened

7. Remove the outer sheath of the coaxial cable (2C-2V) by 75 mm. Pull back

the braided shield to expose the inner core. Remove approx. 25 mm of insu-
lator from the end of inner core and fold back conductor as illustrated below.
Shorten the shield leaving approx. 45 mm. Fit crimp-on lugs to the conductor
(FVD1.25-3, Red) and braided shield (FV1.25-M3, Red).

Coaxial cable

2C-2V

50 mm

45 mm

Fold back the conductor
as illustrated below.

75 mm

Inner core

Conductor

6 mm

Crimp-on lug
FVD1.25-3
(Red,

3)

Crimp-on lug
FV1.25-M3
(Red,

3)

Figure 2-4 Fabrication of coaxial cable

8. Slip the cable gland over the cable and tighten the cable gland nut. Seal the

cable gland nut with putty to preserve watertight integrity.

9. Connect wiring to terminal STB-1 referring to the interconnection diagram.