Foster QC 11 User Manual

Page 11

background image

10

Alarm

ALU

MAXIMUM temperature alarm

30

30

30

30

ALL

Minimum temperature alarm

30

30

30

30

ALd

Temperature alarm delay

60

60

60

60

EdA

Alarm delay after defrost

30

30

30

30

tbA

Silencing alarm relay

YES

YES

YES

YES

Others

Ad1

Address 1 for RS485:

0

0

0

0

Ad2

Address 2 for RS485

1

1

1

1

Lod

Local display

nr

nr

nr

nr

rEd

Remote display

iP

iP

iP

IP

LOC

Keypad LOCK

no

no

no

No

PAS

Security code set up

321

321

321

321

tPb

Type of probe

ntc

ntc

ntc

Ntc

rEL

Release code (readable only)

1,0

1.0

1.0

1.0

Ptb

Parameter code (readable only)

--

--

--

--

Parameter Definitions

REGULATION
Hy Intervention differential for set point:
(0,1

÷ 12,0 /0,1°C/1°F), always positive. Compressor cut IN is Set Point

Plus Differential (Hy). Compressor cut OUT is when the temperature reaches the set point.

AC

Anti-short cycle delay: (0÷30 min) minimum interval between the compressor stop and the following

restart.

1c2 Second compressor setting: (enabled only if OAC=C2)

The fourth relay work as second compressor if OAC=Co2.
Second compressor operates on set + OAS. (whit set= set loaded during the current phase). It starts oAt min.
after the first compressor
The following table shows how it works:

Cycle

Holding

1c2=0

C1 ON; C2 On C1 on; C2 On

1c2=1

C1 on; C2 On

C1 on C2 off

1c2=2

C1 on; C2 off

C1 on; C2 On

1c2=3

C1 on; C2 off

C1 off; C2 On

rPO

Thermostat probe calibration (-12,0

÷ 12,0; res. 0,1 °C /1°F)

EPP Evaporator probe presence (not present in the XB350C): (no / YES) no: not present (timed defrost); YES:

present (end defrost )

EPO Evaporator probe calibration (not present in the XB350C): (-12,0

÷ 12,0; res. 0,1 °C /1°F)

iPP

Insert probe presence (no / YES) no: not present; YES: present.

iPO

Insert probe calibration (-12,0

÷ 12,0; res. 0,1 °C /1°F)

CFTemperature measurement unit: °C =Celsius; °F =Fahrenheit
rES

Resolution (for °C): in: integer; de: with decimal point

PAU Time of stand by: (0

÷ 60min) after this time the controller restart the cycle

PFt

Maximum acceptable duration of power failure: (0

÷ 250 min) if power failure duration is less than PFt,

the cycle restarts from the same point at which it was stopped otherwise the cycle restarts from the beginning of
the current phase.

iPd

Temperature difference for the automatic recognition of the insert probe: (0

÷ 30; ris.1 °C/1°F) if the

difference of temperature between the insert probe and the thermostat probe is less than iPd, the selected cycle
is made by time.

iPt Time delay for the automatic recognition of the insert probe: (0÷255sec, with 0 only timed cycles are done)

time between the start of a cycle and the comparison of the temperature of the thermostat probe and the insert
probe to recognising if the insert probe is used.

Con Compressor ON time with faulty probe: (0

÷ 255 min) time during which the compressor is active in case of

faulty thermostat probe. With COn=0 compressor is always OFF

COF Compressor OFF time with faulty probe: (0÷255 min) time during which the compressor is off in case of

faulty thermostat probe. With COF=0 compressor is always active

diC

Digital input operating mode (EAL, bAL, dor)

EAL: external alarm; bAL: serious alarm; dor: door open function

diP: digital input polarity: (OP÷CL)select if the digital input is activated by opening or closing the contact. OP=

opening; CL=closing

did: digital input delay (0÷255 min) delay between digital input activation and his signalling for configurable or

door opened alarm.
NOTE: with diC=EAL did has to be different from zero.