1. Turn off the TX switch and operate all on-board equipment

one by one while observing the picture.

2. Run the boat at various speeds to check if the noise is speed

dependent.

If neither of the above two steps has effect on the picture, adjust
one of the following:

Interference rejector (data setting window: SIGNAL,
SIGNAL PROCESS)

This control is similar to the interference rejector on echo sound-
ers and radars. It is effective for rejecting random noise and sea
surface reflections in rough sea conditions. Set it so that noise is
just eliminated. Do not use an unnecessarily high setting since it
may also reject small wanted echoes.

Changing Tx cycle (data setting window: TVG•TX,
CYCLE)

When other sonars operate nearby at the same transmission in-
terval as that of own ship’s sonar, an interference ring caused by
other sonars is displayed. To erase the interference ring from
the screen, reduce the CYCLE on the data setting window.

Interference

Tx cycle high Tx cycle lowered

Figure 3-3 How CYCLE works

Note: When the sonar is used in shallow water with the range
set between 60 m and 200 m and Tx cycle at “9”, seabed reflec-
tions caused by the 2nd-to-the-last transmission may appear on
near ranges. Reduce the Tx cycle setting to “2” or “3” to sup-