beautypg.com

Furuno CSH-53 User Manual

Page 14

background image

1-6

Main

Item

Item

Setting

Range

Description

Normal

Setting

Main

Sub

SIGNAL

SIGNAL
PROCESS

NL

0–10

Rejects unwanted echoes.

3

AGC

0–10

Automatically reduces receiver
gain against strong echoes such
as seabed. Adjust so fish echo is
displayed near seabed.

0

2AGC*

0–4

Suppresses seabed echoes. If
AGC alone cannot suppress
seabed echoes, use 2AGC.

0

SIGNAL
PROCESS

CURVE

1–4

Selects echo level versus presen-
tation color curve. The higher
the setting, the easier it is to see
weak echoes on the screen.

2

IR

0–3

Rejects random noise and inter-
ference by other echo sounders
or sonars.

0

AFGLOW

0–4

Adjusts echo afterglow, which is
useful for watching echo move-
ment. The higher the setting the
longer the afterglow remains.

0

ES

ES1
(Net
Recorder)

RANGE
(DN RNG)

16

Pos.

Sets depth range of echo
sounder picture. Sets range of
net recorder downward
sounding.

160 m

GAIN

0–10

Adjusts receive sensitivity.

5

SHIFT
(UP RNG)

0–

1000 m

Sets display start depth of echo
sounder picture. Sets range of
net recorder upward sounding.

0 m

ES1
(Net
Recorder)

NL

0–10

Rejects blue dots (caused by
dirty water) on entire screen.

0

COLOR

0–9

Eliminates echoes displayed in
colors specified.

0

IR

ON,

OFF

Eliminates interference by other
sonars or echo sounders.

OFF

DELETE MK

DELETE
MARK

+ or -

key to

erase.

Each pressing erases oldest mark
among event mark 1, event mark
2, fish mark, own ship mark.

DELETE
MARK

TRACK

Each pressing deletes 1/5 of
overall length.

*2AGC and HOR functions cannot be used together. If one is used the other is
automatically set to “0”.

(Continued on next page)