8. Pressurize sealed system with a combination of R-22

and nitrogen and check for leaks, using a suitable leak

detector. Recover refrigerant per EPA guidelines.

9. Once the sealed system is leak free, install solenoid coil

on new valve and charge the sealed system by weighing

in the proper amount and type of refrigerant as shown

on rating plate. Crimp the process tubes and solder the

ends shut. Do not leave Schrader or piercing valves in

the sealed system.

NOTE: When brazing a reversing valve into the system, it is

of extreme importance that the temperature of the valve does

not exceed 250

°F

at any time.

Wrap the reversing valve with a large rag saturated with

water. “Re-wet” the rag and thoroughly cool the valve after

each brazing operation of the four joints involved.

The wet rag around the reversing valve will eliminate

conduction of heat to the valve body when brazing the line

connection.

6. Protect new valve body from heat while brazing with plastic

heat sink (Thermo Trap) or wrap valve body with wet

rag.

7. Fit all lines into new valve and braze lines into new

valve.

Procedure For Changing Reversing Valve

1. Install Process Tubes. Recover refrigerant from sealed

system. PROPER HANDLING OF RECOVERED

REFRIGERANT ACCORDING TO EPA REGULATIONS

IS REQUIRED.

2. Remove solenoid coil from reversing valve. If coil is to

be reused, protect from heat while changing valve.

3. Unbraze all lines from reversing valve.

4. Clean all excess braze from all tubing so that they will

slip into fittings on new valve.

5. Remove solenoid coil from new valve.

The use of a torch requires extreme care and proper

judgment. Follow all safety recommended precautions

and protect surrounding areas with fire proof materials.

Have a fire extinguisher readily available. Failure to follow

this notice could result in moderate to serious property

damage.

NOTICE

FIRE HAZARD

touch test in Heating/Cooling Cycle

The only definite indications that the slide is in the mid-

position is if all three tubes on the suction side of the valve

are hot after a few minutes of running time.

NOTE: A condition other than those illustrated above, and

on Page 31, indicate that the reversing valve is not shifting

properly. Both tubes shown as hot or cool must be the same

corresponding temperature.

Certain unit components operate at

temperatures hot enough to cause burns.

Proper safety procedures must be followed,

and proper protective clothing must be

worn.

Failure to follow these procedures could

result in minor to moderate injury.

WARNING

BURN HAZARD

Sealed Refrigeration System contains refrigerant

and oil under high pressure.

Proper safety procedures must be followed,

and proper protective clothing must be worn

when working with refrigerants.

Failure to follow these procedures could

result in serious injury or death.

WARNING

HIGH PRESSURE HAZARD

The use of nitrogen requires a pressure

regulator. Follow all safety procedures and

wear protective safety clothing etc.

Failure to follow proper safety procedures

could result in serious injury or death.

WARNING

EXPLOSION HAZARD