beautypg.com

3 pio data-out command protocol – FUJITSU MHZ2250BJ User Manual

Page 254

background image

Interface

5.4.3 PIO data-out command protocol

WRITE MULTI (EXT) (FUA EXT)

WRITE BUFFER

SECURITY DISABLE PASSWORD

SECURITY SET PASSWORD

SET MAX UNLOCK

2) If an error remaining in the device prevents command execution, the device

sends the RegDH FIS with 1 set in the I bit.

Execution of the following commands involves data transfers from the host system
to the device:

WRITE SECTOR (S) (EXT)

WRITE VERIFY

SMART WRITE LOG SECTOR

SECURITY ERASE UNIT

SECURITY UNLOCK

SET MAX SET PASSWORD

DOWNLOAD MICROCODE

WRITE LOG EXT

DEVICE CONFIGRATION SET

Data of one or more sectors is transferred from the host to the device.

An outline of this protocol is as follows:

1) The device receives a PIO data-out command with the RegHD FIS.

3) When the device is ready to receive data, it sets 0 in the BSY bit and 1 in the

DRQ bit of the Status field of the PIO Setup FIS. At this time, the device sets
0 in the I bit of the Status field of the PIO Setup FIS for a data transfer to the
first sector, while it sets 1 in the I bit for a data transfer to any sector other
than the first sector. Then, it sends this FIS to the host. In the E_Status field,
the device sets 1 in the BSY bit and 0 in the DRQ bit.

5-180