beautypg.com

FUJITSU MHZ2250BJ User Manual

Page 225

background image

5.3 Host Commands

Table 5.41 Data format of Read Log Ext log page 11h

Byte(hex) Item

00 to 03

Reserved

04 to 05

Counter 1 Identifier

06 to 09

Counter 1 Value

0A to 0B

Counter 2 Identifier

0C to 0F

Counter 2 Value

... ...

4C to 4D

Counter 10 Identifier

4E to 51

Counter 10 Value

52 to 53

Counter 0 Identifier

54 to 1FE

Reserved

1FF Check

sum

Table 5.42 Counter Identifier information

Identifier Description

0

No counter value : marks end of counters in the page

1

Command failed due to an ICRC error

2

Data FIS R_ERR ending status (transmitted and received)

3

Data FIS R_ERR ending status (transmitted)

4

Data FIS R_ERR ending status (received)

5

Non-data FIS R_ERR ending status (transmitted and received)

6

Non-data FIS R_ERR ending status (transmitted)

8

Non-data FIS retries (transmitted)

9

Transitions from drive PhyRdy to drive PhyNRdy.

A

Signature Device to Host Register FIS sent due to a COMRESET.

B

CRC errors within the FIS (received)

D

Non-CRC errors within the FIS (received)

F

Data FIS R_ERR ending status due to CRC errors (received)

10

Data FIS R_ERR ending status due to non-CRC errors (received)

C141-E280

5-151

This manual is related to the following products: