beautypg.com

Figure 13, N shown in – Fortinet 5003 User Manual

Page 32

background image

FortiSwitch-5003A and 5003 Fabric and Base Backplane Communications Guide

32

01-30000-85717-20081205

Fabric 10-gigabit switching within a chassis

FortiGate-5140 fabric backplane communication

Figure 13: Example 10-gigabit connection between internal and external networks

If the data traffic contains VLAN-tagged packets, you must add the VLAN tags to
the FortiSwitch-5003A interfaces that will handle the VLAN-tagged traffic. For
example, to allow VLAN tags 300 to 305 on slots 9, 11, and 13 and the F7 front
panel interface, from the FortiSwitch-5003A CLI enter:

config switch fabric-channel interface

edit "slot-9"

set allowed-vlans 1,300-305

next
edit "slot-11"

set allowed-vlans 1,300-305

next
edit "slot-13"

set allowed-vlans 1,300-305

next
edit "f7"

set allowed-vlans 1,300-305

end

FortiGate-RTM-XB2

modules installed

in RTM slots 9, 11,

and 13 provide two

10-gigabit fabric

channels and NP2

acceleration

for each

FortiGate-5001A

board

Internal Network

FA N T R AY

FA N T R AY

FA N T R AY

13

11

9

7

5

3

1

2

4

6

8

10

12

14

5140

CRITI

CAL

RESE

T

MAJOR MIN

OR

USER1 USER2 USER3

5140SAP

SERIAL 1

SERIAL 2

ALARM

FILTER

1 2

0

1

2

10/100

link/Act

ETH0

Service

RESET

STATUS

Hot Swap

link/Act

ETH0 ETH1

10/100

5000SM

10/100

link/Act

ETH0

Service

RESET

STATUS

Hot Swap

link/Act

ETH0 ETH1

10/100

5000SM

Fabric channel 1
10-gigabit data
communication

Fabric channel 2
10-gigabit data
communication

External 10-gigabit
network connected
to fabric channel 1

Internal 10-gigabit
network connected to
fabric channel 2

External
Network

FortiGate-RTM-XB2
modules installed
in RTM slots 6, 8,
and 10 provide
two 10-gigabit fabric
channels and NP2
acceleration for each
FortiGate-5001A board

Note: On some versions of the FortiGate-5001A firmware, when a FortiGate-5001A board
starts up with a FortiGate-RTM-XB2 module installed, the fabric1 and fabric2 interfaces are
replaced with interfaces that are named RTM/1 and RTM/2 to indicate the presence of the
FortiGate-RTM-XB2 module. Configuration settings that include the fabric1 and fabric2
interface names will have to be changed to use the RTM/1 and RTM/2 interface names.