beautypg.com

Technical specifications, Quickspecs – HP ProLiant ML350 G5 User Manual

Page 28

background image

System Unit - Tower

Dimensions (HxWxD)
(with feet/bezel)

18.43 x 8.66 x 25.2 in (46.8 x 22 x 64 cm)

Weight (approximate)

60 lb (27.24 kg) (without hard drives)

Input Requirements
(per power supply)

Rated Line Voltage

100-120 VAC / 200-240VAC

Rated Input Frequency 50 Hz to 60 Hz

Input Power

<1000W @ 90VAC
<1050W @ 115VAC
<1205W @ 180VAC

Rated Input Current

10A(100VAC),6.7A(200VAC)

BTU Rating

4112BTU/hr

180VAC

Power Supply Output
Power
(per power
supply)

Rated Steady-State
Power

800W at 120V or 1000W at 220V

Temperature Range

Operating

50° to 95° F (10° to 35° C)
(No direct sustaining sunlight)

Storage (up to one year) -40° to 158° F (-40° to 70° C)

Maximum Wet Bulb
Temperature

82.4° F (28° C)

Relative Humidity
(non-condensing)

Operating

10% to 90%

Non-operating

5% to 90%

Acoustic Noise

Idle Minimum
(Fixed Disk Drives
Spinning)

L WAd (BELS)

6.0

L pAm (dBA)

43

Operating Minimum
(Random Seeks to Fixed
Disks)

L WAd (BELS)

6.0

L pAm (dBA)

43

QuickSpecs

HP ProLiant ML350 G5 Storage Server

Technical Specifications

DA - 12560 Worldwide — Version 3 — March 2, 2007

Page 28