B. clearances – Hearth and Home Technologies I60 User Manual
Page 19

19
B. Clearances
WARNING! Risk of Fire! You must comply with all minimum air space clearances to combustibles as specifi ed in Fig-
ure 6.2. DO NOT pack required air spaces with insulation or other materials.
Heatilator • I60, I80 • 4013-250 • Rev C • 11/08
(insulation)
0 in. to level
of standoffs
Attic
Insulation
Shield
(ceiling)
(roof)
(attic)
(ceiling)
Ceiling Firestop
Offset/Return (secured
with hanger straps)
Storm Collar
Roof Flashing
Clearance to back &
sides of appliance
I60 - 1 in. (25 mm)
I80 - 1 1/2 in. (38 mm)
(except at nailing flanges
where it is 1/2 in. [13 mm])
Must have 2 in. (51 mm)
minimum clearance
to header
0 in.
to floor
2 in. (51 mm) min.
Shaded areas
represent
2 in. (51 mm) min.
air space clearance
required around pipe
Combustible Object
48 in.
1219 mm
Adapter attached here (not shown)
Figure 6.2 Clearances to Combustible Materials
Note: Chimney air kit and 11-10 in./279-254 mm adapter are not shown,
but are required in Canada.