Framing & clearances, A. select fireplace location – Hearth and Home Technologies I60 User Manual
Page 18
18
6
6
Framing & Clearances
F
D
E
A
5/8 in. (16 mm)
all configurations
In an exterior
chase or projecting
into a garage
Across a
corner
As a room
divider
Along a wall
G
B A
G
G
B
A
48 in.
(1219 mm)
min.
H
A
H
Note:
Note:
I60 - 1 in. (25 mm)
I80 - 1 1/2 in. (38 mm)
minimum distance from
sides & back of fireplace to
combustible materials.
I60 & I80 - 1/2 in. (13 mm)
minimum at nailing flanges.
In addition to these
framing dimensions, also
reference the following
sections:
• Clearances (Section
6.B.)
• Mantel Projections
(Section 11.E.)
• Fireplace Dimensions
(Section 13.A.)
C
H
B
Figure 6.1 Fireplace Locations (Framing dimensions shown)
A. Select Fireplace Location
Model
A
B
C
D
E
F
G
H
I60
inches
45 1/2
53 1/2
85
42 1/2
19 3/8
60 1/8
28
24 in. (610 mm)
Minimum from FP opening to any
perpendicular wall.
mm
1156
1359
2159
1080
492
1527
711
I80
inches
52
59 1/2
92 3/4
46 3/8
21 1/2
65 5/8
28 1/2
mm
1308
1511
2356
1178
546
1667
724
Heatilator • I60, I80 • 4013-250 • Rev C • 11/08