2 flue system approvals, Warning, Caution – Hearth and Home Technologies SL-350TRSI-AUE User Manual
Page 8
8
Heat & Glo • SL-350TRSI-AUE • 2089-902 Rev. B • 6/06
TABLE 1
1.2 FLUE SYSTEM APPROVALS
These models have flue starting collars on both the top
and the back of the unit. Depending upon the installa-
tion, decide which ONE set of starting collars will be
used to attach the flue system. The starting collar sealing
cap must remain on the starting collar NOT used.
These models use SL-D-series direct flue components
when using the TOP flue collars and DVP-series direct
flue components when using the REAR flue collars.
WARNING:
YOU MUST NOT MIX DVP-SERIES
AND SL D-SERIES COMPONENTS IN ANY FLUE
SYSTEM CONFIGURATION.
Approved flue system components are labeled for
identification. NO OTHER FLUEING SYSTEMS OR
COMPONENTS MAY BE USED. Detailed installation
instructions are included with each flue termination kit
and should be used in conjunction with this manual. Figure
5 below shows flue system components and terminations.
Identifying Flue Components
The flue systems installed on this gas fireplace may
include one, two, or three 90°
elbow assemblies. The
relationships of vertical rise to horizontal run in flue
configurations using 90° elbows MUST BE strictly
adhered to. The rise to run relationships are shown in
the flueing drawings and tables on the next few pages.
If a 90° elbow is first attached to the unit, the maximum
horizontal run is 2 feet (610mm).
WARNING:
THIS GAS APPLIANCE AND FLUE AS-
SEMBLY MUST FLUE DIRECTLY TO THE OUTSIDE
AND MUST NEVER BE ATTACHED TO A CHIMNEY
SERVING A SEPARATE SOLID FUEL BURNING AP-
PLIANCE. EACH GAS APPLIANCE MUST USE A
SEPARATE FLUE SYSTEM-COMMON FLUE SYS-
TEMS ARE PROHIBITED.
CAUTION:
UNDER NO CONDITION SHOULD
COMBUSTIBLE MATERIAL BE CLOSER THAN 3
INCHES (2 1/2 INCHES (64MM) AT WALL FIRE-
STOPS) FROM THE TOP OF THE PIPE OR 1-INCH
TO THE SIDES AND THE BOTTOM FOR HORIZONTAL
SECTIONS OF THIS FLUE SYSTEM. VERTICAL
SECTIONS OF THIS SYSTEM REQUIRE A MINI-
MUM OF 1-INCH (25MM) CLEARANCE TO COM-
BUSTIBLE MATERIALS ALL AROUND THE PIPE.
For alternative installations, other than depicted, con-
tact your dealer for further information.
Refer to Figure 5 for required clearances to flue terminals.
Flue system termination kits
Flue system components
Figure 6. Flue Components and Terminations
MODEL
SL-350TRSI-AUE
DVP-TRAP2 & SLK-01TRD HORIZONTAL TERMINATION CAP
DVP-TVHW & SLK-991DA VERTICAL TERMINATION CAP
FLUE TERMINATION APPROVALS
VERTICAL
TERMINATION
HORZONTAL
TERMINATION
WALL
FIRESTOP
STORM
COLLAR
ROOF FLASHING
HORIZONTAL PIPE
SUPPORT
PIPE LENGTH
WALL BRACKET
CEILING
FIRESTOP
90 DEGREE
ELBOW
SLK-01TRD
SLK-991DA
DVP-TVHW
DVP-TRAP2
DVP-SERIES
SL D-SERIES