4 ignition system wiring, Warning, Caution – Hearth and Home Technologies SL-350TRSI-AUE User Manual
Page 23
23
Heat & Glo • SL-350TRSI-AUE • 2089-902 Rev. B • 6/06
1.4
IGNITION SYSTEM WIRING
•
This gas heater is equipped with an electronic igni-
tion system which operates on a 6 volt system.
•
This appliance requires 240 VAC to be wired to the
factory installed junction box. Check factory installed
power cord for damage before use.
Figure 31. Electronic Ignition Wiring Diagram
Shock Risk
• Replace damaged wire with type 105°C
rated wire.
• Wire must have high temperature insulation.
WARNING
Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and danger-
ous operation. Verify proper operation after servicing.
CAUTION
IGNITION
MODULE
(6V)
ON/OFF
WALL SWITCH
VALVE
FLAME SPARKER/
SENSOR
ANT.
REMOTE
CONTROL
HOT
NEUTRAL
GROUND
BATTERY PORT
VALVE
PILOT
IGNITION MODULE
6VDC
ON/OFF
SWITCH
THERMOCOUPLE
BLOCK
(CONNECTED TO
BACK OF VALVE)
GAS LINE
CONNECTED TO
BACK OF VALVE
PLUG IN