Replacing modeling light – Hensel Expert D 1000 Flash Kit User Manual
Page 36

User Manual Expert D 500/1000
36
HENSEL-VISIT GmbH & Co. KG
Â
Pull the flash tube out again approximately 0.5 mm so that
the glass body can expand upon warming.
Â
Wrap the wire
B
onto the connecting pin
C
.
Suitable flash tubes for compact flash unit
Expert D 500/1000
,
see chapter „14 Accessories“ on page 40.
Replacing modeling light
The halogen lamp of the compact flash unit’s modeling light is
plug-in. In case of a defect, it can be replaced by the user.
ATTENTION!
Before replacing the halogen lamp, switch off the unit and dis-
connect it from its power supply. Wait at least 15 minutes for the
halogen lamp to cool off.
Avoid touching the flash tube with bare hands to prevent its con
-
tamination with oily residue. This would reduce the flash tubes
operating life. Use cotton gloves instead.
Â
Remove the safety dome, see „Mounting/removing safety
dome“ on page 15.
Â
Carefully pull the lamp from its plug connector.
Â
Insert a suitable lamp.
Ensure that the lamp is fuse protected according to regulation,
see „Replacing fuses“ on page 33.
Maximum modeling lights to be used are:
300W/G6.35/115V resp. 300W/G6.35/230V
The modeling light has to match the voltage of the power sup
-
ply.