User Manual Expert D 500/1000

22

HENSEL-VISIT GmbH & Co. KG

Note:

Based on a multitude of possible electronic circuits in different

cameras which are used for synchronization, we are not liable

for possible damages to the camera used for flash triggering.

Please contact the camera’s manufacturer before using a non-

standard camera for such purpose.

Synchronization via slave

The built-in slave

23

triggers the flash when light from another

flash is detected (slave mode).
This mode of operation is activated/deactivated with the

SLAVE

key

1

. The active setting is indicated via LED above the key.

The slave is an impulse photo cell. It only triggers the flash

when the striking light is brighter than the ambient light.

Note:

Make sure that other bright, ambient light does not reach the

photo cell. If this cannot be avoided, please use a cable or

radio transmitter for synchronization.

Synchronization via radio remote trigger

The optional radio remote triggers

Strobe Wizard Plus

,

free-

mask

and Hensel

Profoto Air are used to conveniently synchro

-

nize the camera and flash unit via radio remote control. See

„14 Accessories“ on page 40.

Â

In this set-up, you have to switch off the slave function with

the

SLAVE

key

1

.

How to operate with optional radio remote triggers is described

in the following chapters.

PM mode

(in connection with Power Max L)

Hallmarks of the compact flash units of the

Expert D

series

are their especially short flash duration times and fast recycling

times - also when operated with a Power Max L. This results in a

comparatively high power draw. In order to guarantee optimum

functioning, the

Expert D

must be switched to a special mode

when used in connection with a Power Max L.