H3C Technologies H3C SecPath U200-A U200-M U200-S User Manual
Page 22
13
Item Requirements
Result
EMI prevention
•
Take effective measures to protect the power
system from the power grid system.
•
Separate the protection ground of the UTM
device from the grounding UTM device or
lightning protection grounding UTM device as far
as possible.
•
Keep the UTM device far away from radio
stations, radar and high-frequency UTM devices
working in high current.
•
Use electromagnetic shielding when necessary.
Lightning
protection
•
The grounding cable of the chassis is well
grounded.
•
The grounding terminal of the AC power
receptacle is well grounded.
•
A port lightning arrester is installed. (Optional)
•
A power lightning arrester is installed. (Optional)
Electricity safety
•
Equip an uninterrupted power supply (UPS).
•
In case of emergency during operation, switch off
the external power switch.
Space
•
Reserve at least 10 cm (3.94 in) of clearance at
the air inlet and exhaust vents for ventilation.
•
The rack or workbench has a good ventilation
system.
Workbench
The workbench is sturdy and well grounded.
Rack-mounting
requirements
•
Install the UTM device in an open rack if possible.
If you install the UTM device in a closed cabinet,
make sure the cabinet is equipped with a good
ventilation system.
•
The rack is sturdy enough to support the weight of
the UTM device and installation accessories.
•
The size of the rack is appropriate for the UTM
device.
•
The front and rear of the rack are at least 0.8 m
(2.62 ft) away from walls or other UTM devices.
Safety
recommendations
•
Do not place the switch near water or in a damp environment.
Prevent water or moisture from entering the switch chassis.
•
Locate the emergency power-off switch in the room before
installation. Shut the power off at once in case accident occurs.
Tools
•
Installation accessories supplied with the UTM device
•
User supplied tools
Reference
•
Documents shipped with the UTM device
•
Online documents