Property Damage: All tubes must be cut
squarely with no burrs.
Attach supplied quick connect elbow
to end of supplied white 1/4" tube.
Attach quick connect elbow to water
Inlet on front of chilled water tank.
Measure distance from water inlet
on chilled water tank to water
supply valve. Carefully trim
white 1/4" tube, allowing
ample slack in tubing.
Brass Nut
Ferrule
Brass Insert
Brass Nut
Ferrule
Plastic
tube
1
4
Inlet
Outlet
White Tape
HOW TO USE THIS INSTRUCTION MANUAL
These instructions are separated into main sections, indicated by numbers, and
subsections, indicated by capital letters. The manual is setup this way to allow you to
take a break at any point after completing a section or subsection without affecting the
installation process.
What you’ll see in the
instruction manual:
1
2
3
Equipment You May Need:
IMPORTANT: After unpacking chilled water tank, place the unit upright for 1 hour before
connecting power.
For best results, the cold water faucet should be installed prior to installing the chilled water tank.
The C1100 Cold Only Faucet is designed for use with the CWT-00 Chilled Water Tank as a system (with
optional InSinkErator Filtration System).
For your satisfaction and safety, read all instructions, cautions and warnings before installing or using
this chilled water tank.
This particular unit is not intended for commercial use.
Make sure that all electrical wiring and connections conform to local codes.
A standard 115-volt grounded electrical outlet is required under the sink for the chilled water tank’s
electrical power.
It is recommended that a separate circuit providing power only to the chilled water tank be used.
The wall outlet powering the chilled water tank must be fused and should not be controlled by the same wall
switch used by the food waste disposer.
It is recommended that a dedicated control valve be installed on the cold water line supplying water to this
system. Make sure all water supply control valves do
not have a backflow preventer in them.
If you suspect elevated levels of chlorine in your water, it is recommended to use our water filtration system.
The water pressure to the chilled water tank should be between a minimum of 30 psi (207kPa) and
a maximum of 100 psi (689kPa).
The chilled water tank may cause an increase in temperature in your cabinet when running.
The chilled water tank has a refrigeration compressor, which may generate noise while running.
The chilled water tank should only be installed in an upright position.
The chilled water tank is intended only for chilling water.
WHAT YOU SHOULD KNOW BEFORE YOU BEGIN
If you will be installing a dedicated cold only water faucet and intend to use the sprayer hole in your sink for that
faucet, you may need a basin wrench and a 1/8" plug or a 1/4" hose line cap (
not supplied).
If you need to cut a mounting hole in your stainless steel sink, you may need a 1-1⁄4" – 1-1⁄2" hole saw made
for cutting stainless steel or a hole punch. Consult a professional if you are drilling into a surface other than
stainless steel.
Equipment Required:
(sold separately)
n
Cold water faucet
n
T-fitting
n
Dedicated control valve
n
Adjustable wrench
n
Utility knife
n
Tape measure / ruler
WHAT YOU NEED TO GET STARTED
Provides a step-by-step narrative describing the installation step, with check boxes that
can be marked as you progress through the installation.
Contains simple illustrations that provide visual instruction to support the narrative.
CAUTIONS and WARNINGS that will require your attention during the step.
1
2
3
A potentially hazardous situation, which, if not avoided, could result in death or serious injury.
Caution, used with the safety alert symbol, indicates a hazardous situation which, if not
avoided, could result in minor or moderate injury.
Caution, without the safety alert symbol, is used to address practices not related to
personal injury.
PACKAGE COMPONENTS
Chilled Water Tank
Quick Connect Elbows (3)
White Tubing - 4'
Blue Tubing - 4'
Cold Only Faucet
Rubber O-Ring
Hex Nut
Semi-circular
Mounting Plate
1/4" Brass Insert
Hex Tool
CWT-00
C1100
Y-Quick Connector
Plug (1)
Congratulations on your purchase of this quality InSinkErator
®
water product. In addition
to complete operating and care instructions, in this Owner’s Manual you will find instructions
for installing both:
• CWT-00 Chilled Water Tank with an existing hot/cool water dispenser – See pages 4-6
• CWT-00 Chilled Water Tank with a C1100 Cold Only Faucet – See pages 7-9
3
2
Hole saw / hole punch Basin wrench 1/4" Tube insert, ferrule and nut