Wx-101a control features/mounting control center, Features, Mounting the control center – InSinkErator WX-300 User Manual

Page 5

background image

6

The WX-101A Control Center is UL

®

approved for use

with InSinkErator Waste Xpress food waste reduction
systems. The control center operates the disposer and
Waste Xpress. Its main functions are:

• To start and stop the disposer/Waste Xpress system.

• To reverse the direction of the disposer motor
automatically upon restart.

• To start the water fl ow to the disposer.

• To allow water fl ow for several minutes to fl ush the
drain line after the disposer is turned off.

Model

Part No.

Voltage

Phase

WX-101A-1

14479

120V

1

WX-101A-2

14479A

208/230V

1

WX-101A-3

14479B

208/230V

3

WX-101A-4

14479C

380/460V

3

FEATURES

SINGLE BUTTON OPERATION
Disposer and Waste Xpress are controlled by simple
ON/OFF button operation.

AUTOMATIC REVERSE
The disposer motor will reverse its direction of
rotation automatically upon restart. To avoid motor
damage, a delay feature prevents reversing until
the post fl ush is complete.

WATER SHUTOFF DELAY (POST FLUSH)
After the motor is turned off, the water continues to
fl ow for up to 10 minutes. The length of this post fl ush
is controlled by the water shutoff delay timer. The post
fl ush helps ensure that ground food waste is fl ushed
out of the drain line.

AUTOMATIC TIMED DISPOSER SHUTOFF
This water saving feature allows the system to run for
10 minutes before it automatically shuts off and must
be manually restarted.

LINE DISCONNECT SWITCH
The switch on the front panel of the control center
disconnects the line voltage. It interlocks with the front
cover so that the cover cannot be opened unless the
switch is in the off position.

LOW VOLTAGE CONTROL
Control operates on a 24 V solid state control circuit.

ENCLOSURE
Stainless steel NEMA 4 construction.

WX TIMER HOT WATER SPRAY ADJUSTABLE
Factory set for 2 minutes off 10 second on controls hot
water spray for cleaning of screen.

Table 1. Electrical Specifi cations

WX-101A Control Features/Mounting Control Center

MOUNTING THE CONTROL CENTER

Use the fl anges at the back of the control center
enclosure and only mount panel in the upright vertical
position (door hinge is on the left). See Figure 4.

Locate control center within sight of disposer per
local codes.

If box is mounted to the sink table, recess the box so
that the buttons do not extend beyond the table’s edge
(see Figure 4).

15 1/8"

14"

15 3/4"

9 7/8"

8 1/4"

5 1/4"

6 3/4"

5 5/16"

1"

Figure 4. Control Center Dimensions

ELECTRICAL SHOCK

• Ensure that Waste Xpress voltage and phase match

that of the electrical supply, control center &
disposer. Check nameplate for specifi cation.

• Electrical connections should be made by a

qualifi ed electrician and should comply with all
local codes.

• Turn off electrical supply to Waste Xpress,

control center & disposer before attempting to
work on it. Test with a volt meter or circuit tester
to ensure that power is off.

• Do not operate unit with panels removed.

• All components (disposer, WX, control center

and solenoids) must be carefully and permanently
grounded.

• A properly fused disconnect must be installed at

Waste Xpress, control center & disposer electrical
supply source.

• Use only NEMA 4 watertight electrical connectors

when connecting to junction box.