PERSONAL INJURY

Wait until auger paddles stop before cleaning
Waste Xpress.

1. Press stop button on control center to stop system

(disposer & Waste Xpress).

2. Holding both handles remove discharge chute by

tilting it upward (see Figure 25).

3. Remove auger-bearing bracket by sliding the two

captive fasteners inward and then pull bracket
upward (see Figure 26 and 27).

4. Lift auger and screen up and then out

(see Figure 26).

5. Remove auger from screen by lifting it up and out

(see Figure 28).

6. Rinse auger, screen, auger compartment and

discharge chute. Auger, screen and discharge
chute are dishwasher safe and should be washed
daily. Flush inlet and outlet with a fresh water
supply to keep the drain lines clean.

7. Install auger into screen then place screen

over drive.

8. Ensure that the auger drops into position.

9. Secure bearing bracket with captive fasteners.

10. Install discharge chute by placing bottom, front

portion in fi rst and then tilting back and downward.

Figure 25.

Figure 26.

Figure 27. Bearing Bracket

Figure 28.