beautypg.com

Operation, Wiring diagram, Use with sitesync iq – American Time Wired Tone Generator User Manual

Page 7: Multi tone generator, Contact information operation specifications, American time

background image

7

© American Time

Multi Tone Generator

Contact

Information

Operation

Specifications

Operation

Use with SiteSync IQ

®

System Controllers

The tone generator can also be used in conjunction with the SiteSync IQ System Controller to schedule

the triggering of tones. This can be done by hardwiring the tone generator to the SiteSync IQ System

Controller or wirelessly through the SiteSync IQ transmitter.

The unit can be triggered by wiring the desired T1-T4 combinations to the NO terminal of one of the six

bell circuits located on the back of the SiteSync IQ system controller. The COM terminal of the system

controller bell circuit should then be connected to the C terminal (Tone Selection Common). The user

can now set up circuit events on the SiteSync IQ system controller which control when and how long

the desired tone is triggered off and on.

n

Note: See the SiteSync IQ Wireless Installation Manual before installation. Also, verify that the

system controller you have has the bell circuit option.

REAR OF SY

STEM C

ONTR

OLLER

COM

NO

NC

NC

COM

NO

NO

COM

NO

COM

COM

NO

NO

COM

NO

COM

NO

COM

CLOCK 1

CLOCK 2

BELL 1

BELL 2

BELL 3

BELL 4

BELL 5

BELL 6

GAIN

T1

T2

T3

T4

PA/AMP

IN

COM

Red (+)

Blk (-)

COM

COM

SPKR

SPKR

AUDIO IN

AUDIO OUT

(+)

(-)

12VDC

Multi-T

one Generator

(500 mA max)

1-800-328-8996 www

.atsclock.com

Wiring Diagram