Radio modules – ZENNER EDC – Electronic Data Capture Modul User Manual
Page 11

11
Number of digit rollers
Pulse value
Counter with 8 digit with modulator disc
1 rotation = 1 litre
6-digit counter with modulator disc (DN50-DN125)
1 rotation = 10 litres
6-digit counter with modulator disc (DN150-DN200)
1 rotation = 100 litres
6-digit counter with modulator disc (> DN300)
1 rotation = 1.000 litres
Pulse value of the modulator disc depending on the meter value
Data telegram contents (wM-Bus, M-Bus)
The EDC module can be delivered with various
data telegrams:
Data protocols
Type
A
Type
B
Type
C
Current value
✘
✘
✘
Current data
✘
✘
Due date
✘
✘
✘
Monthly value
✘
✘
✘
Further 11 monthly
values
✘
Status information 1
✘
✘
✘
Status information 2
✘
✘
✘
5. Radio modules
The EDC wireless M-Bus radio modules are
available in T-(standard), optionally in S- or C-
mode. Various data telegrams are available. The
modules operate unidirectional and usually send
every 20 seconds. Special versions possible.
Setting parameters:
■
Current status of the roller counter (register)
■
The water meter number related to the EDC
module
■
Pulse value of the modulator disc
■
Resetting of the status bits (tampering, error)
■
Resetting of all logger values (in case of re-
placement of the water meter and further use
of the EDC module)
Activation performs automatically, as soon as the
function "pulse enabled" is activated and the EDC
module scans 30 pulses from the register. The
current status of the roller counter is programma-
ble by means of the optical head using the front-
mounted optical interface of the EDC module.
The ZENNER PC-software GlobalMeterManager
(GMM) is required for programming. The configu-
ration is made by means of the GMM licence, the
universal interface MinoConnectRadio with Blue-
tooth interface and the specific ZENNER infrared
optohead IrCombiHead.
Technical specifications EDC-radio:
Transmission
mode
wireless M-Bus unidirectional,
T1 (standard), optionally
S1, C
Encryption code
AES-128 nach OMS
(device specific, optionally
customer specific)
Telegram
contents
rent value, due date, current
month value, history of the
monthly values, status
information
Transmission
interval
typically 20 s;
other configurations possible
Transmission
power
25 mW