beautypg.com

ZENNER zelsius C5 IUF User Manual

Page 3

background image

3

MID - Initial verification

zelsius

®

C5-IUF is produced and tested in

compliance with the new European Measuring
Instruments Directive (MID). According to this
directive, devices are no longer carrying an ini-

tial verification stamp, but rather the year of the
device’s declaration of conformity (recognizable
on the front of the device, for example: M12).
The MID controls the use of heat meters up to
the moment they are placed on the market resp.

Technical data calculator

Temperature range

°C

0...105 / 0...150 *

Temperature difference range

K

3...80 / 3...130 *

Display

LCD 8-stellig + Sonderzeichen

Ambient temperature during operation

°C

5...55

Storage temperature

°C

-20...+65

Resolution temperature

°C

0,01

Measurement frequency

s

adjustable ex works, beginning with 2s, standard 32s

Unit to read the heat consumption

Standard MWh; optionally kWh, GJ

Data storage

1 x daily

Due date values

Storage of all monthly values during the entire operation time

Maximum value storage

extensive storage of flow rate, performance and other parameters

Interface

Standard

Optical interface (ZVEI, IrDA), 3 Pulseinputs/-outputs

optional

M-Bus, wM-Bus, RS485, radio

Supply

3,6 V lithium battery (different capacities)

Battery lifetime

Years

> 6, opt. > 11 (changeable during the operation time)

Protection class

IP54

EMC

A

Ambient conditions/climatic

influencing (valid for complete

compact meter)

- climatic

Highest permissible ambient temperature 55°C,

Lowest permissible ambient temperature 5°C,

Humidity class IP54

- mechanical class

M1

- electro-magnetic class

E1

Dimensioning limits may apply for non-symetrical temperature sensors installation.

* optionally

Technical data temperature sensors

Platinum precision resistor

Pt 1000

Sensor diameter type

mm

45 x 5,0 mm / 45 x 5,2 mm / DS 27,5 more on request

Temperature range

°C

0 – 105/0…150

Cable length

m

1,5 (opt. 5)

Installation

VL

by direct immersion or by immersion sleeves (in case of existing measuring points)

RL

by direct immersion or by immersion sleeves (in case of existing measuring points)

Integrated in the flow sensor, optionally external