ZENNER zelsius C5 IUF User Manual
Page 10
![background image](https://www.manualsdir.com/files/771142/content/doc010.png)
10
Important Note:
The optical interface has to be activated by
means of the OptoHead through keypress before
reading out of the de vice.
Devices, which are in sleep mode (Display:
SLEEP 1) have to be activated through keypress
until the energy display shows up.
Depending on you meter’s model its displays
can differ in number and order from those shown
here.
Level 1
Level 2
Heat energy
(Main display)
Ebene 1
Ebene 2
Ebene 3
Ebene 4
Volume
Supply temperature
Return temperature
Temperature difference
Flow rate
Current output
Certification model
3
Pulse value
Input 1
4
Pulse value
Input 2
4
Pulse value
Input 3
4
Sensor type and
installation point VMT
3
Model number
Serial number
End of the battery
Error status
3
System Date
3
System Time
3
Operation hours
3
Primary M-Bus address
3
Firmware version
3
Function
Output 3
3
Function
Output 2
3
Function
Output 1
3
Date month maximal
flow
2
2
Maximum power, Average value
since commissioning
Maximum heat energy
power month
2
2
Maximum cooling energy
power month
Maximum cooling energy power,
average value since commissioning
2
Heat energy difference from
last due date to now
2
Cooling energy difference
from last due date to now
Heat energy difference from
1. this month to now
2
Maximal Flow
2
2
Cooling energy difference from
1. this month to now
2
Volume difference from
1. this month to now
Due date cooling energy
1
Cooling energy
1
3
Opto readout energy
2
S
S
S
S
H
H
H
H
Ebenenwechsel können
jedem beliebigen Menü-
punkt heraus erfolgen.
Hinweis
Je nach Ausführung Ihres Zählers können Anzeigen in Anzahl und
Reihenfolge von den Abbildungen mehr oder weniger abweichen.
Legende
Taste kurz drücken (S), zum
Blättern von oben nach un-
ten. Nach unterstem Menü-
punkt erfolgt ein automati-
scher Sprung zum obersten
Menüpunkt (Schleife).
Taste etwa 2 sec. drücken
(L), warten bis Türsymbol
(oben rechts in der Anzeige)
erscheint, dann Taste loslas-
sen. Erst dann wird Menü
aktualisiert bzw. erfolgt der
Sprung zum Untermenü.
Taste halten (H) bis Ebenen-
wechsel oder Rück sprung
aus Untermenüs erfolgt.
H
L
S
1
3
1
3
1
3
3
3
Segment test
1
2
3
4
1
Energy
Last due date
1
Date last due date
Heat energy
(Main display)
Ebene 1
Ebene 2
Ebene 3
Ebene 4
Volume
Supply temperature
Return temperature
Temperature difference
Flow rate
Current output
Certification model
3
Pulse value
Input 1
4
Pulse value
Input 2
4
Pulse value
Input 3
4
Sensor type and
installation point VMT
3
Model number
Serial number
End of the battery
Error status
3
System Date
3
System Time
3
Operation hours
3
Primary M-Bus address
3
Firmware version
3
Function
Output 3
3
Function
Output 2
3
Function
Output 1
3
Date month maximal
flow
2
2
Maximum power, Average value
since commissioning
Maximum heat energy
power month
2
2
Maximum cooling energy
power month
Maximum cooling energy power,
average value since commissioning
2
Heat energy difference from
last due date to now
2
Cooling energy difference
from last due date to now
Heat energy difference from
1. this month to now
2
Maximal Flow
2
2
Cooling energy difference from
1. this month to now
2
Volume difference from
1. this month to now
Due date cooling energy
1
Cooling energy
1
3
Opto readout energy
2
S
S
S
S
H
H
H
H
Ebenenwechsel können
jedem beliebigen Menü-
punkt heraus erfolgen.
Hinweis
Je nach Ausführung Ihres Zählers können Anzeigen in Anzahl und
Reihenfolge von den Abbildungen mehr oder weniger abweichen.
Legende
Taste kurz drücken (S), zum
Blättern von oben nach un-
ten. Nach unterstem Menü-
punkt erfolgt ein automati-
scher Sprung zum obersten
Menüpunkt (Schleife).
Taste etwa 2 sec. drücken
(L), warten bis Türsymbol
(oben rechts in der Anzeige)
erscheint, dann Taste loslas-
sen. Erst dann wird Menü
aktualisiert bzw. erfolgt der
Sprung zum Untermenü.
Taste halten (H) bis Ebenen-
wechsel oder Rück sprung
aus Untermenüs erfolgt.
H
L
S
1
3
1
3
1
3
3
3
Segment test
1
2
3
4
1
Energy
Last due date
1
Date last due date