General notes

Watermeters are precision instruments. Protect

against shock and vibration. Storage under cool, dry

and frost free conditions.

Thesealingsurfacesareequippedwiththreadpro-

tectioncaps,andthusprotectedfromdamage.

Check and ensure before beginning the installation:

– Thatthesealingfacesareflatandfreefromda-

mage such as notches, grooves, etc..

– Thatallindicationsonthedialarereadble*.

– Themeterfitsintype,size,temperatureandpres-

sureratingtotheinstallationandmeteringpoint.

Withpollutedorloadedwaterwerecommendthat

filters or strainers in the inlet must be installed

upstreamofthemeter.

Themetershouldalwaysbeinstalledatthelowest

possiblepointofthepipingaswellasfrostprotec-

ted,topreventtheaccumulationofairanddama-

ges.

Thewatermetermustbeinstalledintothepipeline

free of any of mechanical forces or tensions.

Watermeters must be operating completely filled

with water - for wet dial meters this includes also

thecounter!

Themetermustbeprotectedwithappropriatemea-

suresagainstpressureshocksinthepipeline.

Whenthereisdangeroffrost,emptycompletelyand

shutofftheinstallation(includingthemeter),ifne-

cessary, dismount the meter.

Themetermustalwaysbeeasilyaccessibleandle-

gible, including all indications on the dial.

We recommend that the installation points on the

pipelineshouldbesecuredwithasealagainstunau-

thorizeddismounting.Thesealshouldnotberemo-

vableorloosenedwithoutvisibledamage.

Theinstallationhastobedonebyqualifiprofessi-

onal personnel. We would refer to the applicable

rulesoftheDINISO4064:2015,Part5.

Installation:

1. Readtheseinstructionscarefullyrightuptothe

end!

2. Closevalvesupstreamanddownstreamofthe

meter.

3. Releasepressureattheinstallationpoint.

4. Dismount existing meters or meter blanks.

5. Useonlynewandflawlesssealingmaterial.

6. Check the seal face for damage.

7. Install the new meter according to the correct

flowdirection and installation position. Ensure

that the sealing joints do not fall out, or are being

damaged.

8. Screwtheconnectionnutsandtightenthem.

9. Openvalescarefullyandavoidpressureshocks,

purgeadequately.

10. Checkinstallationforleakage.Thedialandthe

indications regarding the conformity /metrology

must be visible and readable at any time.

Additional instructions for installation of plas-
tic meter:

In order to guarantee a stress-free installation,

werecommendtheuseofawatermeterinstalla-

tionbracket(WZAG).

Recommended tightening torque for the connec-

tors:min.20Nmuptomax.30Nm.

Declaration of conformity

ZENNERInternationalGmbH&Co.KG

declaresthattheproductwiththenumberof

oneoftheECtype-examinationcertificates

DE-06-MI001-PTB005,DE-06-MI001-PTB006,

DE-07-MI001-PTB009,DE-08-MI001-PTB016,

DE-08-MI001-PTB017,DE-07-MI001-PTB010,

DE-13-MI001-PTB001,DE-15-MI001-PTB004,

CH-MI001-10040 or CH-MI001-14062 com-

plieswiththeessentialrequirementsoftheEC

directive 2004/22/EC (Measuring instruments

directive).

ZENNERInternationalGmbH&Co.KGherebyde-

clares that the product for Remote Metering with

theapplicationWirelessCommunicationscomplies

withtheessentialrequirementsoftheECdirective

1999/5/CE(R&TTE).

Themostup-to-dateinformationaboutthisproduct

can be found at

www.zenner.com

English

*Dataregardingtheflowratesaredependingontherespectivenominalsize.

This manual is related to the following products: