MAINTENANCE (continued)
3. Disconnect the 2 hoses from the Saltwater System, and assemble the cell cover (10) at each
side of the cell.
4. In a counter-clockwise motion, unscrew the collar of the copper electrode (5) and remove it
from the electrolytic cell (4). Lift up the copper electrode.
5. Pour kitchen grade vinegar into the cell to immerse the titanium plates. Then put the copper
electrode back in the cell, soak them for about one hour until no colored areas remain.
6. Open one side of the cell cover (10), drain and properly dispose of the vinegar. Connect the
hose which goes from the pool to the cell. Flush the cell with the pool water.
7. Reverse steps 3, 4, 5 and 6 to reconnect the electrolytic cell.